Code. 020503
Instructions.
Rated temperature:80℃;
Rated voltage:300V;
Reference standard: UL758,UL1581;
Marks:E318342 UL AWM 2468 XX AWG 80℃ 300V VW-1 YI MEI TE LF;
Specification: Use 32~16AWG tinned or bare copper strands;
Insulation: PVC;
Banded parallel flat wire: within spacing between 2.0mm and 2.5mm, convenient to insert into every socket on PCB, can work as substitute of wire harness; has passed through ULVW-1 flammability test.
Application: Suitable to wiring in electronics or electric appliance e.g. acoustic or video equipment, etc…
Working temperature:-20℃~80℃.
Remarks: Table of marks for the cores with spacing of 1.5mm and 1.6mm.
2C |
3C |
4C |
5C |
6C |
7C |
8C |
9C |
10C |
11C |
12C |
— |
× |
- |
。 |
| |
+ |
—- |
×— |
-| |
+— |
×— |
Product construction and typical functional parameters:
Spacing (mm) |
Conductor |
Insulation |
Maximum conductor DC resistance (Ω/Kft,20℃) |
Minimum insulation resistance (MΩ-km,20℃) |
Pressure resistance (ACV,1min) |
Core number |
American wire gauge (AWG) |
Construction (No/mm) |
External diameter (mm) |
Thickness (mm) |
External diameter (mm) |
1.5 |
2 |
26 |
7/0.160 |
0.48 |
0.46 |
1.40×2.90 |
44 |
15 |
1,600 |
3 |
7/0.160 |
0.48 |
0.46 |
1.40×4.40 |
4 |
7/0.160 |
0.48 |
0.46 |
1.40×5.90 |
5 |
7/0.160 |
0.48 |
0.46 |
1.40×7.40 |
6 |
7/0.160 |
0.48 |
0.46 |
1.40×8.90 |
7 |
7/0.160 |
0.48 |
0.46 |
1.40×10.40 |
8 |
7/0.160 |
0.48 |
0.46 |
1.40×11.90 |
9 |
7/0.160 |
0.48 |
0.46 |
1.40×13.40 |
10 |
7/0.160 |
0.48 |
0.46 |
1.40×14.90 |
11 |
7/0.160 |
0.48 |
0.46 |
1.40×16.40 |
12 |
7/0.160 |
0.48 |
0.46 |
1.40×17.90 |
2.0 |
2 |
26 |
7/0.160 |
0.48 |
0.46 |
1.40×3.40 |
44 |
15 |
1,600 |
3 |
7/0.160 |
0.48 |
0.46 |
1.40×5.40 |
4 |
7/0.160 |
0.48 |
0.46 |
1.40×7.40 |
5 |
7/0.160 |
0.48 |
0.46 |
1.40×9.40 |
6 |
7/0.160 |
0.48 |
0.46 |
1.40×11.40 |
7 |
7/0.160 |
0.48 |
0.46 |
1.40×13.40 |
8 |
7/0.160 |
0.48 |
0.46 |
1.40×15.40 |
9 |
7/0.160 |
0.48 |
0.46 |
1.40×17.40 |
10 |
7/0.160 |
0.48 |
0.46 |
1.40×19.40 |
2.5 |
2 |
26 |
7/0.160 |
0.48 |
0.46 |
1.40×3.90 |
44 |
15 |
1,600 |
3 |
7/0.160 |
0.48 |
0.46 |
1.40×6.40 |
4 |
7/0.160 |
0.48 |
0.46 |
1.40×8.90 |
5 |
7/0.160 |
0.48 |
0.46 |
1.40×11.40 |
6 |
7/0.160 |
0.48 |
0.46 |
1.40×13.90 |
7 |
7/0.160 |
0.48 |
0.46 |
1.40×16.40 |
8 |
7/0.160 |
0.48 |
0.46 |
1.40×18.90 |
9 |
7/0.160 |
0.48 |
0.46 |
1.40×21.40 |
10 |
7/0.160 |
0.48 |
0.46 |
1.40×23.90 |
Product construction and typical functional parameters:
Spacing(mm) |
Conductor |
Insulation |
Maximum conductor DC resistance (Ω/Kft,20℃) |
Minimum insulation resistance (MΩ-km,20℃) |
Pressure resistance (ACV,1min) |
Core number |
American wire gauge (AWG) |
Construction (No/mm) |
External diameter (mm) |
Thickness (mm) |
External diameter (mm) |
1.5 |
2 |
24 |
7/0.203 |
0.61 |
0.45 |
1.50×3.10 |
27.7 |
15 |
1,600 |
3 |
7/0.203 |
0.61 |
0.45 |
1.50×4.70 |
4 |
7/0.203 |
0.61 |
0.45 |
1.50×6.30 |
5 |
7/0.203 |
0.61 |
0.45 |
1.50×7.90 |
6 |
7/0.203 |
0.61 |
0.45 |
1.50×9.50 |
7 |
7/0.203 |
0.61 |
0.45 |
1.50×11.10 |
8 |
7/0.203 |
0.61 |
0.45 |
1.50×12.70 |
9 |
7/0.203 |
0.61 |
0.45 |
1.50×14.30 |
10 |
7/0.203 |
0.61 |
0.45 |
1.50×15.90 |
11 |
7/0.203 |
0.61 |
0.45 |
1.50×17.50 |
12 |
7/0.203 |
0.61 |
0.45 |
1.50×19.10 |
2.0 |
2 |
24 |
7/0.203 |
0.61 |
0.45 |
1.50×3.50 |
27.7 |
15 |
1,600 |
3 |
7/0.203 |
0.61 |
0.45 |
1.50×5.50 |
4 |
7/0.203 |
0.61 |
0.45 |
1.50×7.50 |
5 |
7/0.203 |
0.61 |
0.45 |
1.50×9.50 |
6 |
7/0.203 |
0.61 |
0.45 |
1.50×11.50 |
7 |
7/0.203 |
0.61 |
0.45 |
1.50×13.50 |
8 |
7/0.203 |
0.61 |
0.45 |
1.50×15.50 |
9 |
7/0.203 |
0.61 |
0.45 |
1.50×17.50 |
10 |
7/0.203 |
0.61 |
0.45 |
1.50×19.50 |
2.5 |
2 |
24 |
7/0.203 |
0.61 |
0.45 |
1.50×4.00 |
27.7 |
15 |
1,600 |
3 |
7/0.203 |
0.61 |
0.45 |
1.50×6.50 |
4 |
7/0.203 |
0.61 |
0.45 |
1.50×9.00 |
5 |
7/0.203 |
0.61 |
0.45 |
1.50×11.50 |
6 |
7/0.203 |
0.61 |
0.45 |
1.50×14.00 |
7 |
7/0.203 |
0.61 |
0.45 |
1.50×16.50 |
8 |
7/0.203 |
0.61 |
0.45 |
1.50×19.00 |
9 |
7/0.203 |
0.61 |
0.45 |
1.50×21.50 |
10 |
7/0.203 |
0.61 |
0.45 |
1.50×24.00 |